UPS Systems

3 Phase UPS Solutions

SLC-CUBE3 + 7.5KVA TO 200KVA, Superior Protection for Critical Systems

SLC-CUBE3 + 7.5KVA TO 200KVA, Superior Protection for Critical Systems

  • 400v Input, 400v Output
  • 400v Input, 230v Output Max 60kva
  • 230v Input, 400v Output Max 60kva
  • 50 Hertz
  • 0.9 Output Power Factor < 120kva
  • On-Line Topology
  • ECO Mode
  • Parallel up to 4 Units
  • Sinewave Output EPO
  • Audible Alarms/Alarm Card Software
  • Extended Battery Autonomies Network Card Compatible
SLC-ADAPT (MODULAR) 10KVA TO 900KVA

SLC-ADAPT (MODULAR) 10KVA TO 900KVA

  • On-Line Double Conversion with Modular Architecture
  • 10, 15, 20, 25, 30KVA Modules
  • 3, 6, 10 Module Systems (up to 300kva)
  • Parallel / Redundant Operation up to 900kva
  • Voltage Options 400v/400v, 400v/230v, 230v/230v
  • Input Power Factor >0.99
  • Input Current Distortion (THDi) <3%
  • Hot-Pluggable and Swappable Plug & Play Modules
  • EPO
  • Software
  • Network Card Compatible
SLC-XTRA 100KVA TO 800KVA, Protection for Major Critical Applications

SLC-XTRA 100KVA TO 800KVA, Protection for Major Critical Applications

  • 400v Input, 400v Output
  • 50 Hertz
  • >0.99 Input Power Factor
  • 0.9 Output Power Factor
  • On-Line Topology
  • ECO Mode
  • Parallel up to 8 units
  • Pure Sinewave Output
  • Audible Alarms/Alarm Card
  • Extended Battery Autonomies
  • EPO
  • Software
  • Network Card Compatible

UPS Single Phase Solutions

SPS-SOHO + 400VA to 2000VA, Home and Small Office It Protection

SPS-SOHO + 400VA to 2000VA, Home and Small Office It Protection

  • 230v Input, 230v Output
  • 50 or 60 Hertz
  • Line interactive Topology
  • Tower version
  • Simulated Sinewave Inverter
  • Transfer Time 2 to 6ms
  • IEC Adapter Outputs
  • Audible Alarms
  • Internal Batteries only
  • Cold Start
SPS-Advance RT 700VA to 3000VA, Protection for Network and IT Servers

SPS-Advance RT 700VA to 3000VA, Protection for Network and IT Servers

  • 230v Input, 230v Output
  • Buck Boost Stabiliser
  • Tower and Rack Versions
  • Sinewave Output
  • Transfer Time 2 to 6ms
  • IEC Outlets
  • Audible Alarms/Alarm Card
  • Extended Battery Autonomies
  • EPO
  • Software
  • Network Card Compatible
SLC-Twin-Pro 700VA to 20KVA Maximum On-Line Protection

SLC-Twin-Pro 700VA to 20KVA Maximum On-Line Protection

  • 230v Input, 230v Output
  • 400v Input, 230v Output
  • 50 or 60 Hertz
  • 0.9 Output Power Factor
  • On-Line Topology
  • Parallel up to 4 Units from 4kva
  • Sinewave Output
  • Audible Alarms/Alarm Card
  • Extended Battery Autonomies
  • EPO
  • Software
  • Network Card Compatible
SLC-Twin-RT 700VA to 10KVA Maximum On-Line Protection

SLC-Twin-RT 700VA to 10KVA Maximum On-Line Protection

  • 230v Input, 230v Output
  • 400v Input, 230v Output
  • 50 or 60 Hertz
  • 0.9 Output Power Factor
  • On-Line Topology
  • Parallel up to 4 units from 4kva
  • Sinewave Output
  • Audible Alarms/Alarm Card
  • Extended Battery Autonomies
  • EPO
  • Software
  • Network Card Compatible